Analysis Code | Analysis Name | Explanation | Price |
---|---|---|---|
11-01-01 | Heat Capacity Measurement (with DSC) | Appointment is required | 300 TL |
11-01-02 | Determination of Melting Point and Glass Transition Temperature-between ambient temperature - 500 C temperatures (with DSC) | Appointment is required | 360 TL |
11-01-03 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC) | Appointment is required | 240 TL |
11-02-01 | Dew Point Temperature Measurement | Determination of dew point temperature in systems where humid air is used | 60 TL |
11-03-01 | Viscosity Measurement | Fluidity determination | 120 TL |
11-04-01 | Heat Conduction Coefficient Measurement | Measuring range: 0.026-12 W/mK Minimum sample size: 2x6x12 cm | 156 TL |
11-05-01 | Silica Measurement | Measuring range: 1 - 100 mg/L SiO 2 | 144 TL |
11-11-01 | Particle Count | Determination of airborne particle count | 180 TL |
11-12-01 | Building Indoor Air Quality Monitor | CO 2 , CO, Temperature, Relative Humidity | 240 TL |
11-13-01 | Thermal Comfort System | It is used to measure temperature, air velocity, relative humidity, operative temperature, radiation temperature and dry heat loss temperature, which are among the indoor air quality parameters that must be measured in order to determine comfort conditions. | 1200 TL |
11-21-01 | Downhole Temperature Measurement (per measurement) | Get information from the expert | 1800 TL |
11-21-01 | Downhole Pressure Measurement (per measurement) | Get information from the expert | 1800 TL |
11-22-01 | Tracer tests | It is used to determine the flow rate and groundwater flow direction. | 6000 TL |
11-23-01 | Radon Level Measurement (per point) | It is used for Radon gas determination in water, air and soil. | 240 TL |
11-31-01 | Radiation Intensity Data | Solar radiation intensity: 0-1800 W/m 2 | 360 TL |
11-31-02 | Temperature (Min., Max., Avg.) Data | Temperature measurement range: (-40) -60 °C | 360 TL |
11-31-03 | Relative Humidity Data | Relative humidity measuring range: 0-100% | 360 TL |
11-31-04 | Wind Direction and Intensity Data | Wind speed and direction: 1- 67 m/s and 0-360 ° | 360 TL |
11-41-01 | Flue Gas Analyzer | 600 TL | |
11-42-01 | Thermal Camera | Electrical, mechanical, insulation and handles all the problems with temperature in an open mechanism is used to instantly detect and diagnose. | 600 TL |
11-43-01 | Conductivity Meter | 120 TL | |
11-44-01 | Steam Trap Tester | Used to detect steam leaks | 180 TL |
11-45-01 | Infrared Temperature Meter (Low Temperature) | Temperature measurement range: (-32) -420 °C | 120 TL |
11-46-01 | Infrared Temperature Meter (High Temperature) | Temperature measurement range: 200-1800 °C | 120 TL |
11-47-01 | Electronic Temperature Meters and Probes | Probes: Surface temperature probe, ambient temperature probe, skewer type temperature probe | 300 TL |
11-48-01 | Ultrasonic Flow Meter | It is used to measure the flow of geothermal fluid inside the pipe. | 300 TL |
11-49-01 | Electronic Relative Humidity Meter | Portable textile moisture measuring device | 120 TL |
11-50-01 | Pitot Tube and Inclined Manometer | 120 TL | |
11-51-01 | Hot Wire Air Velocity Meter (Device and Probe) | Used to measure air velocity, temperature, volumetric air flow, relative humidity and pressure | 120 TL |
11-52-01 | Propeller Type Air Velocity Meter | It is used to measure and record air velocity and temperature in air ducts. | 120 TL |
11-53-01 | Current Clamp | Current meter | 60 TL |
11-54-01 | Tachometer | 60 TL | |
11-55-01 | Lux-meter | Light intensity measurement | 120 TL |
11-56-01 | Sound Level Meter (hour) | Used to determine the level of noise in various environments | 180 TL |
11-57-01 | Data Logger (12-channel, 4-channel) | The price is determined depending on the duration of use. | It is determined depending on the usage period. |
11-61-01 | Geothermal Data Assessment Report | Interpretation of hydrological data from geothermal fields | 3600 TL |
11-61-02 | Geothermal Resource Protection Area Report | It will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters Law | 18.000 TL |
11-61-03 | 1 / 25.000 Scale Hydrogeological Report (1km 2 ) | Includes the preparation of 1/25.000 scaled Hydrogeological Map for 1 km 2 area and report | 3.600 TL |
11-61-04 | Preparation of 1 / 25.000 scaled Geological Maps and Sections that will be the basis for the exploration project of geothermal resources or natural mineral waters | It will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters | 18.000 TL |
11-61-05 | Reservoir Modeling Study and Evaluation and Report Preparation of the geothermal resource (includes geology, geophysics, geochemistry, well logs, interpretation of hydrogeology data and modeling of the system) | Covers geology, geophysics, geochemistry, well logs, hydrogeology data interpretation and system modeling | 42.000 TL |